IEC 60332 Wire Cable Flammability Chamber

IEC 60332 Wire Cable Flammability Chamber

This test chamber is used to determine the vertical burning characteristics of wire cable or optical fiber.
Chat Now

Product Details

Standards 

IEC 60332 ,GB/T19666-2005,  GB12972, GB13033, MT818,MT386, ISO5656 


This equipment is used to determine the vertical burning characteristics 

of wire cable or optical fiber. 


Features

7inch full color programmable touch screen+PLC 

Automatically record the test time, automatically display the test results, automatic timing, 

automatic ignition, the Bunsen burner automatically returns after the flame is over, operator 

can choose whether to turn off the gas or not

When starting, can choose whether to auto-ignite; start, stop, gas, timing, ignition, save, save, 

lighting, exhaust are all operated by touch screen control

 

 

Specifications

1. Burner: I.D Φ9.5mm ± 0.5mm

2. Test angle: 45°The sample beam can be moved back and forth, and the 

position of the Bunsen burner can be adjusted according to the size of the sample

3. Flame height: 20mm ± 2mm  to 190mm±1mm adjustable 

4. Burning time 0-999.9s±0.1sadjustable

5. Burning gas: 95% propane gas (liquefied petroleum gas can be used as an alternative)

6. Sample length: 600±25mm

7. Sample outer diameter: Conductor diameter greater than 0.8mm or cross-sectional area greater than 0.5mm2

8. This device should be tested in an environment with no ventilation and a temperature of (23 ± 10) ℃

9. Bunsen burner power:1KW 

10. Power supply:220V/50Hz

11. Gas flow: 0-1L/min

12. Air flow:1.5-15L/min

13. Enclosure material: Steel plate electrostatic spraying ( stainless steel  optional)

14. Overall size: L60 cm×W45cm× H15 6cm


Inquiry